TCR Engineering Services, Material Testing, Laboratory, Outsource Analytical, India
material testing
Material Testing

NABL Scope of Accreditation - Non Ferrous Metals
Copper Base - Chemical and Mechanical

Specific Tests performed on Copper Base products/ Materials

Test method / standard against which tests are performed

Range of testing / Limits of detection

Accuracy (ฑ)

Copper (Pure) Vogel–3–1975
IS 440 – 96
Up to 99.99 1%
Copper
(cu base alloy)
IS 3685 – 66
IS 4027 – 87
Vogel–3–1975
Up to 97 1%
Tin IS 440 – 96
AAS(ASTM E 63–86)
0.001 to 0.1
0.1 to 0.5
0.5 to 1
1 to 10
10 to 20
10%
10%
5%
1%
2%
Zinc IS 440 – 96
Vogel –3–1975
AAS(ASTM E 63–86)
0.001 to 0.1
0.1 to 0.5
0.5 to 1
1 to 10
10%
10%
5%
1%
Lead IS 3685 – 66
AAS (ASTM E 63–86)
Vogel –3–1975
Up to 0.1
0.1 to 0.5
0.5 to 5
5 to 25
10%
10%
5%
2%
Iron IS 440 – 96
3685 – 66
AAS (ASTM E 63–86)
Up to 0.1
0.1 to 0.5
0.5 to 1
1 to 8
10%
10%
5%
1%
Nickel IS 440 – 96
3685 – 66
AAS (ASTM E 63–86)
Up to 0.1
0.1 to 0.5
0.5 to 1
1 to 10
10 to 40
10%
10%
5%
1%
2%
Aluminum IS 3685 – 66
AAS (ASTM E 63–86)
Up to 0.1
0.1 to 0.5
0.5 to 2
2 to 15
10%
10%
5%
2%
Manganese AAS (ASTM E 63–86) Up to 0.5
0.5 to 2
2 to 5
5 to 15
10%
10%
1%
2%
Carbon LECO Up to 0.5 10%
Sulphur LECO Up to 0.1 5%
Phosphorus IS 440 – 96
IS 4027 – 87
IS 3685 – 66
Up to 0.05
0.05 to 0.1
0.1 to 2
10%
10%
1%
Arsenic AAS (ASTM E 63–86)
Vogel–3–1975
IS 440 – 96
Up to 0.2
0.2 to 0.5
0.5 to 2
10%
5%
4%
Cobalt AAS (ASTM E 63–86) Up to 0.1
0.1 to 0.5
10%
5%
Antimony AAS (ASTM E 63–86) Up to 0.1 10%
Silver AAS (ASTM E 63–86)
Vogel–3–1975
Up to 0.1
0.1 to 2
2 to 20
10%
5%
3%
Cadmium AAS (ASTM E 63–86)
Vogel–3–1975
Up to 0.2
0.2 to 1
10%
5%
Beryllium AAS (ASTM E 63–86)
Vogel–3–1975
Up to 0.5
0.5 to 3
5%
4%
Bismuth AAS (ASTM E 63–86)
Vogel–3–1975IS 440 – 96
Up to 0.1 10%
Silicon Vogel–3–1975 Up to 0.5
0.5 to 2
5%
4%
Chromium AAS (ASTM E 63–86)
Vogel–3–1975
Up to 0.2
0.2 to 2
10%
0.05
Fe, Ni, Al, Mn,Co,Sb, Ag, Cd, Be, Bi, Cr TCR/MTH/02 (ICP)