tcr-materials-testing-machine-shop-lathe.jpg
  Caption: The in-house machine shop. Specimens are cut, milled and ground to the test standard before a single reading is taken.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-mechanical-testing-tensile-frame.jpg
  Caption: Tensile testing to ASTM E8/E8M and IS 1608, on a calibrated universal testing machine.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-mechanical-testing-charpy-impact.jpg
  Caption: Charpy V-notch impact testing to ASTM E23, with sub-zero conditioning where the specification calls for it.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-chemical-analysis-oes-spectrometer.jpg
  Caption: Optical emission spectrometry. The first answer on any unknown alloy, in minutes rather than hours.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-chemical-analysis-icp-spectrometer.jpg
  Caption: ICP spectrometry for trace and residual elements, where OES reaches its detection limit.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-chemical-analysis-pmi-field.jpg
  Caption: Positive material identification on the asset, not on a coupon. The alloy is confirmed where it is installed.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-metallurgical-microscope-bench.jpg
  Caption: Reading the microstructure. Grain size, phase balance, decarburisation and the evidence of service temperature.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-metallurgical-specimen-polishing.jpg
  Caption: Preparation decides the answer. A specimen that is not polished flat and etched correctly reads as a different material.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-corrosion-nace-autoclaves.jpg
  Caption: Sour-service autoclaves. NACE TM0177 and TM0284 exposures run to the full standard duration, not an accelerated proxy.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-corrosion-salt-spray-chamber.jpg
  Caption: Salt spray to ISO 9227 and ASTM B117, including 720-hour acetic acid exposures on architectural coatings.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-fatigue-test-frame.jpg
  Caption: Servo-hydraulic fatigue and fracture toughness, to ASTM E466, E606 and E1820.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-welder-qualification-booth.jpg
  Caption: Welder and procedure qualification coupons, welded and then tested under one roof.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-tmt-rebar-coupler-test.jpg
  Caption: Rebar and coupler testing to IS 16172, all diameters from 8 mm to 40 mm.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-ndt-radiography-exposure.jpg
  Caption: Industrial radiography under AERB licence, in the exposure room and on site.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-ndt-film-interpretation.jpg
  Caption: Film interpretation by an ASNT Level II or III signatory. The reading is the deliverable, not the exposure.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-replica-field-reading.jpg
  Caption: In-situ replication. Over 100,000 replicas read without cutting a single component out of service.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-tpi-dimensional-check.jpg
  Caption: Dimensional and visual inspection at the fabricator's works, against the approved drawing and the ITP.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-source-verification.jpg
  Caption: Source and vendor inspection. The consignment is verified before it ships, not after it arrives.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-machine-shop-floor.jpg
  Caption: The machine shop at Mahape. Lathes, CNC wire-cut, milling, surface grinding and stress-free grinding, under one roof with the test benches.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-machine-shop-personnel.jpg
  Caption: Specimens are machined by the people who know what the standard asks for, not to a generic drawing.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-machine-shop-mahape.jpg
  Caption: Cutting to the standard: gauge length, radius and surface finish are set by ASTM, ISO or IS, not by the workshop.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-materials-testing-hardness-tester.jpg
  Caption: A bench hardness tester. The load and the dwell time come from the test standard, not from the operator.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-ndt-film-hanger-darkroom.jpg
  Caption: Radiography ends in a film somebody has to read. The lead identification on each one ties the shot back to the component it came from.
  Credit:  TCR Engineering Services Pvt. Ltd.

tcr-civil-testing-rebar-caliper.jpg
  Caption: Rib geometry on a deformed reinforcement bar, measured with a digital vernier caliper. On a reinforcement bar the dimensions are part of the acceptance criteria, not a note beside them.
  Credit:  TCR Engineering Services Pvt. Ltd.

TERMS OF USE
  These photographs are TCR's own property and are published here for editorial use: news reporting, trade and technical press, analyst notes, and conference or teaching material about TCR or the industries it works in.
  Carry the credit line printed under the image. Crop and resize as the layout needs, but do not composite, retouch, colourise or otherwise alter the picture, and do not use it in advertising, in an endorsement, or to illustrate a story about another company.
  Where a photograph shows a named person, that name is in the caption. Do not attach a name to a face this page has not named.