+91 98335 30200  ·  sales@tcreng.com

Insights · power-generation

Training on "Boiler Tube Failures: Mechanism and Mitigation"

2013-09-05 · 2 min read · By TCR Newsroom

TCR Advanced Engineering banner over a photograph of failed and corroded boiler tubes

Article

TCR Advanced Engineering ran a two-day training course, Boiler Tube Failures: Mechanism and Mitigation, at its laboratory in Makarpura, Vadodara, Gujarat, India, on 6 and 7 September 2013. The course covered the damage mechanisms behind boiler tube failures, how failure analysis reads them and how a mitigation follows from the finding, for plant, inspection and materials engineers.

TCR Advanced in Vadodara conducted a two-day training on "Boiler Tube Failures: Mechanism and Mitigation" on 6 and 7 September 2013.

TCR Advanced Engineering banner over a photograph of failed and corroded boiler tubes
TCR Advanced Engineering banner over a photograph of failed and corroded boiler tubes

Course Need:

  • Understanding will be developed for different damage mechanism prevailing in the boiler tube failures.
  • Gain a valuable working understanding of fundamental principles of degradation that occurs in short term and long term operation of boilers.
  • Knowledge to increase the problem solving attitude and take the first hand judgement on the boiler tube failures.
  • Analysis of the difference in metal behaviour, to decide the mitigation for a persistent boiler tube failure.
  • Recognise general procedures, techniques and precautions in failure analysis and how stress systems relate to fracture of ductile and brittle materials.
  • Achieve the knowledge required to conduct or supervise basic failure investigation and to communicate with metallurgists and other specialists on more complicated cases, with the aim of improving the reliability of plant operations.
TCR Advanced Engineering brochure for the two-day boiler tube failure course at Vadodara, September 2013: title, venue, dates, course need and who should attend
TCR Advanced Engineering brochure for the two-day boiler tube failure course at Vadodara, September 2013: title, venue, dates, course need and who should attend

Who the Course Was For

· Mechanical Engineers of middle management level

· Maintenance / Inspection Engineers

· Process engineers

· Boiler inspectors

· Plant Engineers / Managers

· QA / QC Engineers

· Reliability Engineer

· Metallurgical / Materials Engineers

· HAZOP Engineers / Managers

· Other Technical, Laboratory, Sales Personnel, Engineer from other disciplines, management and administrative staff who need a working understanding of metals and their applications.

Registration:

Places on the course were limited and were allotted in the order registrations arrived. Participants made their own arrangements for accommodation and local conveyance, and a change in nomination was accepted. The course included participation, course material and stationery, with tea, coffee and a working lunch.

FAQ

Who ran the Boiler Tube Failures: Mechanism and Mitigation course?

TCR Advanced Engineering ran it at its laboratory in Makarpura, Vadodara, Gujarat, on 6 and 7 September 2013. TCR Advanced is a group company of TCR Engineering under common promoters, and its boiler failure investigation and remaining life assessment work is the casework a course of this kind draws on.

What did the course cover?

The damage mechanisms behind boiler tube failures in short-term and long-term operation, the principles of degradation in boiler steels, how failure analysis relates stress systems to ductile and brittle fracture, and how a finding leads to the mitigation of a persistent failure. It was written for engineers who conduct or supervise basic failure investigations.

Does the TCR group still train engineers on boiler tube failures?

Yes. Evolve by TCR, the training academy of TCR Advanced Engineering in Vadodara, established in 2017, runs boiler-plant and in-plant programmes. UltraTech Cement’s programme on minimising boiler tube leakages ran at Vadodara on 26 and 27 May 2025 and closed with a practical demonstration of tube failure analysis.

Send us the failed tube. We have read 1,500 of them.

Request a Quote
Chat on WhatsApp