+91 98335 30200  ·  sales@tcreng.com
Macro view of a steel fracture surface, a smooth fatigue pre-crack band giving way to rough ductile tearing

Services · Materials Testing

CTOD Testing per BS 7448, ISO 12135 and ASTM E1820

A weld can pass radiography, tensile and Charpy tests and still fracture from a flaw it was allowed to keep. CTOD is the toughness number an Engineering Critical Assessment uses to decide which flaws are safe.


Request a Quote

Overview

TCR Engineering runs crack tip opening displacement (CTOD) testing on weld metal, heat-affected zone and parent plate at its Navi Mumbai laboratory, to BS 7448, ISO 15653, ISO 12135, BS 8571 and ASTM E1820, all inside NABL certificate NABLT0726MH18640. Tests run at room temperature, sub-zero, cryogenic down to -70 °C, and after H2S hydrogen pre-charging.

What CTOD Measures and When a Specification Asks for It

CTOD is how far the faces of a sharp crack open at its tip before the crack starts to grow. It measures toughness in the presence of a flaw, which a Charpy energy cannot. Specifications call for it wherever a weld must carry a flaw it is allowed to keep: thick sections, low temperatures and high stresses.

  • Pipelines: API 1104 Annex A, where CTOD on weld metal and heat-affected zone sets the flaw acceptance criteria of an Engineering Critical Assessment.
  • Offshore structures: ONGC Specification 2009F Rev. 8, where CTOD with a fracture mechanics assessment can support welding without post-weld heat treatment, with the Company's written approval.
  • Operator and consultant specifications: ONGC, EIL, DNV and API specifications call for CTOD on welded coupons.
  • Pipe mills: seamless and welded line pipe qualified against a project specification, often with a third-party witness.
  • Defence: high strength steel weld coupons for naval programmes.

Standards and NABL Scope

Every CTOD method TCR runs is on its NABL ISO/IEC 17025:2017 scope, certificate NABLT0726MH18640, so the report carries the accreditation for the method the specification names. Where a specification names an older edition, such as the 1991 edition of BS 7448, the report states the edition tested to.

StandardWhat it coversNABL scope
BS 7448 Parts 1 to 4KIc, critical CTOD and critical J: metallic materials (Part 1), welds (Part 2), high loading rates (Part 3) and resistance curves (Part 4)On the scope, all four parts
ISO 15653Fracture toughness of welds: notch placement in weld metal and heat-affected zone, and the checks that prove itOn the scope
ISO 12135The unified method for quasistatic fracture toughness of metallic materialsOn the scope
BS 8571CTOD and J on single edge notched tension (SENT) specimensOn the scope
ASTM E1820Fracture toughness measurement: J, CTOD and KIc on SENB and C(T) specimensOn the scope
ASTM E1290The former ASTM CTOD method, now carried in ASTM E1820 and still named by older specificationsOn the scope

Specimens, Notch Location and the Fatigue Pre-crack

A CTOD value is only as good as the place its crack tip sits. The specimen is machined so the notch lands in the zone the specification names, weld metal or heat-affected zone. A fatigue pre-crack is then grown from the notch at room temperature, before the specimen is brought to test temperature and loaded.

  1. Specimen. Single edge notched bend (SENB) specimens, usually B x 2B, or compact tension C(T) specimens, machined in TCR's own machine shop. Thickness 8 mm to 32 mm across the full temperature range, 8 mm to 50 mm at room temperature, and SENB over 50 mm to 100 mm, depending on the strength of the material.
  2. Notch position. Weld centreline, fusion line or a set distance into the heat-affected zone, as the specification requires. For a weld metal test, at least 75 per cent of the crack front must lie in the weld metal.
  3. Fatigue pre-crack. Grown in air at room temperature under controlled cyclic load, so the crack is sharp and the specimen is not overloaded.
  4. Crack front. After the test the specimen is broken open and the pre-crack front is measured through the thickness: at nine points under ISO 15653 and ISO 12135, or at 25, 50 and 75 per cent of thickness with crack-to-notch angles where the order asks for it.
  5. Notch location confirmed. Post-test metallography sections the specimen to show where the crack tip actually sat. On a heat-affected zone notch, that section is what makes the result valid.

Setting Up a Weld Metal CTOD Programme

A weld metal CTOD programme is fixed by the standard, the weld condition, the test temperature, the acceptance value and the number of specimens. A representative set-up: ISO 15653 weld metal CTOD on a 65 mm butt weld in the as-welded condition, tested at -10 °C against a 0.25 mm minimum, one set of three specimens.

ItemSet-up
Standard and notchISO 15653, notch in the weld metal
Weld conditionAs welded, no post-weld heat treatment
TemperatureFatigue pre-crack grown at room temperature; test at -10 °C
AcceptanceMinimum CTOD 0.25 mm
SpecimensOne set of three
ReportCTOD value, load versus COD record and the initial crack length a0; optical metallography of the notch position where required
WitnessClient witnesses can attend the test

As-welded thick coupons carry residual stresses that can bow the fatigue pre-crack front and take a specimen outside the straightness limits. ISO 15653 addresses residual stress in weld specimens; state in the enquiry which method, if any, the specification requires, so it is agreed before the plate is cut.

Sizing the Test Plate

Each B x 2B SENB specimen for a 65 mm weld comes from a blank 140 mm wide, the full plate thickness and 700 mm long, cut across the weld with the seam at its centre. One set of three needs three such blanks, and machining takes 2 to 4 mm off the thickness.

Illustration of a 700 mm by 550 mm butt-welded test plate with the weld seam across its middle and three 140 mm blanks marked across the weld, 30 mm discarded at each edge, and a remainder too short for a retest blank.
Illustration: three B x 2B blanks across the weld of a 700 mm x 550 mm test plate, 30 mm discarded at each edge. Not a client drawing.
  • One plate, one set: a 700 mm x 550 mm plate with the seam across it gives exactly three 140 mm blanks once 30 mm is discarded from each edge, and nothing for a retest.
  • Send for retests at the start: supply enough plate for a retest set with the first consignment, so a retest does not wait for new welding.
  • B x B specimens: about 75 mm wide x full thickness x 350 mm per blank, but ISO 12135 recommends B x B only for material 75 mm and thicker; on a 65 mm weld it is an exception the client must accept.

Test Temperatures

The test temperature comes from the minimum design temperature of the structure, and a CTOD result belongs to that temperature only. TCR runs CTOD at room temperature, at sub-zero temperatures in the cold chamber, at -45 °C for welding electrodes, and in cryogenic programmes down to -70 °C.

TemperatureTypical programme
Room temperatureASTM E1820 CTOD on C(T) specimens; thick weld coupons, 30 mm to 70 mm
0 °CONGC Specification 2009F Rev. 8, where the welding procedure must reach at least 0.20 mm; seamless tube qualification against a 0.2 mm minimum on base metal
Down to -20 °CSub-zero CTOD in the cold chamber; weld coupons 8 mm to 30 mm thick
-45 °CWelding electrodes E7018 and E7018-1, on plates welded to the procedure being qualified
Down to -70 °CCryogenic CTOD for Arctic, LNG and offshore material qualification

CTOD After H2S Hydrogen Pre-charging

In wet hydrogen sulphide service, hydrogen diffuses into the weld and lowers its toughness. TCR's procedure, developed for Larsen and Toubro, charges the pre-cracked specimen in H2S before the CTOD test, so the result is the toughness the weld keeps in service rather than in clean air.

  1. Charge. At least 96 hours fully immersed in NACE TM0177 Solution A saturated with H2S.
  2. Transfer. Loading starts within 20 minutes of removal from the solution. A specimen that misses the window goes back into solution for at least 24 hours.
  3. Test. CTOD per ISO 15653, ISO 12135 or BS 8571, then the fracture face is examined for hydrogen damage and reported with the CTOD value.
  4. Compare. Where the specification asks for both, CTOD in air and after charging on the same weld show how much toughness hydrogen takes away.

The H2S bench is the one that runs HIC and SSC qualification on the corrosion and sour service page; hydrogen embrittlement that does not come from H2S, such as cylinder steel and plated parts, is on the hydrogen embrittlement page.

CTOD Programmes Delivered

TCR Engineering has delivered CTOD programmes for three Indian pipe mills, a UAE marine engineering contractor and DRDO's Naval Materials Research Laboratory. The orders show what buyers check beyond the CTOD value: that the notch sits where intended, that the fatigue pre-crack front is measured through the thickness, and that the test is witnessed and reported under NABL.

Client and yearScope and standard
Welspun Corp Limited, Anjar, Gujarat (Barossa project)
2023
24 CTOD tests on SENB specimens with straight notch, up to 25 mm thick, with load versus clip-gauge (COD) records; 6 optical metallography examinations to confirm notch location after fracture
Standard: Client project specification
Aries Marine & Engineering Services LLC, Sharjah, UAE
2023
CTOD at room temperature, at maximum load, on a C(T) specimen with straight notch, 8.0 mm thick, machined by TCR
Standard: ASTM E1820
Jindal SAW Limited, Seamless Tubes Division, Nashik
2024
Two sets of three specimens, one longitudinal and one transverse, at 0 °C against a 0.2 mm minimum on base metal; fatigue pre-crack front measured at 25, 50 and 75 % of thickness with crack-to-notch angles; witnessed by a third-party inspector and reported under NABL
Standard: BS 7448 (1991 edition specified)
Maharashtra Seamless Limited, Roha
2025
Six CTOD specimens for seamless line pipe to API 5L (46th edition), with machining and full fatigue pre-crack front data
Standard: BS 7448
Naval Materials Research Laboratory (NMRL), DRDO, Ministry of Defence, Ambernath
2024 to 2027
CTOD on 29 specimens from high strength steel weld coupons up to 70 mm thick, at room temperature and sub-zero (30 mm to 70 mm at room temperature, 8 mm to 30 mm down to -20 °C); the same contract covers tensile, Charpy, bend, radiography, chemical analysis and metallography of the coupons
Standard: ASTM E1820; ASTM E8M, E23, E190, E94

For Saudi Aramco's Jafurah gas compression plants (PWIS Package-1, 2024 to 2025), six CTOD tests per pipeline on pre-cracked specimens were the fracture toughness input to the ECA of 42-inch girth welds per API 1104 Annex A Option 2. Defence work runs under long-term contracts from NMRL and DMRL, with approvals from CQAE, DRDO.

What to Send Before Testing

Most CTOD delays start before the sample arrives: a test plate welded at the wrong heat input, or too little parent metal to machine the specimen with its notch on the weld centreline. Agree the standard, the notch positions, the temperature and the specimen count before the plate is welded.

  • Test plates welded to the procedure being qualified, with enough parent metal either side for a B x 2B specimen. For electrode qualification, plates of 250 mm x 25 mm x 250 mm with the weld at the centre.
  • The specification and its clause: standard and edition, notch positions, test temperature, acceptance value and any witness requirement.
  • Specimen count: at least three valid specimens per notch position, and six where CTOD in air and after H2S charging are both required.
  • For ONGC work: a test plate whose carbon equivalent is within 0.02 of the maximum production value, welded at the highest production heat input.
  • International shipments: the shipping invoice states that the material has no commercial value and is sent for testing only.

What the CTOD Report Records

A CTOD report has to let a fracture mechanics engineer use the number without calling the laboratory. It carries the value and its type, the record it was calculated from, and the evidence that the specimen was valid: crack front shape, notch location and the temperature the specimen was actually at.

  • The CTOD value and its type: δc, δu or δm.
  • The load versus crack mouth opening (clip gauge) record.
  • Specimen dimensions, orientation and notch position.
  • Pre-crack front measurements and the validity checks of the standard.
  • Post-test metallography photomicrographs, where ordered.
  • The standard and edition, the decision rule and the NABL accreditation.
  • Conformity to a minimum such as 0.25 mm is stated with a simple acceptance decision rule, measurement uncertainty not considered, unless the client asks for a guard band; a guard band is applied per ILAC G8:09/2019 at 1U.

Related insights

7 published insights on this site bear directly on CTOD Testing. The 6 most recent are below; the full index carries all 163 Materials Testing insights.

Read all 163 Materials Testing insights →All insights →

Frequently asked questions

What is a CTOD test?

Crack tip opening displacement is a fracture toughness test. A specimen with a sharp fatigue pre-crack is loaded at the specified temperature, and the opening at the crack tip is measured where the crack starts to grow unstably or the load peaks. The value, in millimetres, feeds a fitness-for-purpose assessment of flaws.

Which CTOD standards are on TCR's NABL scope?

BS 7448 Parts 1 to 4, ISO 15653, ISO 12135, BS 8571, ASTM E1820 and ASTM E1290 are all on NABL certificate NABLT0726MH18640 at the Navi Mumbai laboratory, so a CTOD report to any of them carries the accreditation.

How cold can TCR run a CTOD test?

Room temperature and sub-zero to -20 °C are routine in the cold chamber, welding electrodes are qualified at -45 °C, and cryogenic programmes for Arctic, LNG and offshore qualification run down to -70 °C. The temperature comes from the specification, not from the laboratory.

Can TCR test CTOD after H2S pre-charging?

Yes. Specimens are charged for at least 96 hours in NACE TM0177 Solution A saturated with H2S and loaded within 20 minutes of removal, per ISO 15653, ISO 12135 or BS 8571. The procedure was developed for Larsen and Toubro.

How many CTOD specimens are needed?

At least three valid specimens per notch position for most specifications, and six where results in air and after H2S charging are both required. The ECA coupons of an API 1104 Annex A assessment carry six CTOD tests per pipeline, across weld metal and heat-affected zone.

Do as-welded thick coupons need special preparation before CTOD?

They can. As-welded thick coupons carry residual stresses that can bow the fatigue pre-crack front, and ISO 15653 addresses residual stress in weld specimens. State in the enquiry which method, if any, the specification requires, so it is agreed before the plate is cut.

Know how large a flaw the weld can carry.

Request a Quote
Chat on WhatsApp